We design, build and install stability test chambers for pharmaceutical use (Drug and Medicine Tests). These Photostability chambers are specifically designed to perform near UV and visual light testing with fluorescent lamps.
Features:
- Conform to ICH, WHO Guideline, and USFDA Standards
- Printer interface for LUX & UV meter
- Automatic shut off after specified exposure level
- Mirror finished stainless Steel interior chamber
- Powder coated high grades stainless steel construction
Control System:
Imported Microprocessor based PID controller with digital display of SET and Process value of temperature and humidity. The control panel consists of circuit breaker, dry / wet heater and compressor with indication lamps. Non-volatile memory to allow chamber to return to original set point when power is restored in the event of power failure.
Doors:
Inner glass door user can easily view samples inside without any botheration. Outer door is solid and made of M.S, 304 or 316 grades stainless steel. Door is fitted with magnetic gasket and locking system.
Humidity Generation:
Heater based humidity generator with float valve controlled water reservoir. Steam is conducted into the inner chamber by means of conduits from the Humidity Generator. An additional device, water failure protection is fitted for flawless performance. This device disconnects heater supply in case of water supply failure and starts automatically when the water supply resumes.
Specifications:
Models |
LTI-PSC-4 |
LTI-PSC-6 |
LTI-PSC-9 |
LTI-PSC-16 |
LTI-PSC-35 |
Capacity (Liters) |
100 Liters |
170 Liters |
255 Liters |
450 Liters |
1000 Liters |
Capacity (Cubic Feet) |
4 Cu. Ft. |
6 Cu. Ft. |
9 Cu. Ft. |
16 Cu. Ft. |
35 Cu. Ft. |
Temperature Range |
10°C to 50°C |
||||
Temperature Accuracy |
±0.1°C - ±1°C |
||||
Humidity Range |
20 to 90 % RH |
||||
Humidity Accuracy |
±2%RH - ±3%RH |
||||
Display |
LCD / LED Display |
||||
Resolution |
0.1°C - 1%RH |
||||
Temperature sensor |
PT - 100 |
||||
Control |
Microprocessor PID Controller |
||||
RH sensor |
Direct capacitance type |
||||
Heating |
‘U’ shaped Nichrome wire heater in SS sheathing |
||||
Cooling |
CFC free Copeland make compressor utilizing R 134A eco friendly refrigerant, with condenser, motor and relay |
||||
Air circulation |
Flange motor with impeller / blower |
||||
Chamber illumination |
Fluorescent light with door switch |
||||
Illumination |
1.2 Million LUX Hours |
||||
Construction |
Double Walled |
||||
Construction Material |
M.S. / 304 Grades Stainless Steel (Powder Coated) |
||||
Shelves |
Made of Stainless Steel wire |
||||
Number of Shelves |
2 to 5 (Extra Trays on Demand) |
||||
Power Supply |
230 / 240 Volts |
||||
Standards |
ICH, WHO Guideline, and USFDA |
||||
Caster Wheels |
Optional |
||||
Safety features |
High temperature safety cut off |